  Datasheet File OCR Text:
  signalsure 30 is a compact, surface-mount, low power led signaling solution that delivers an elevated standard of light output, fu x density, and color uniformity. signalsures robust design structure, cou pled with high performance specifcations, ensures high quality and reliab ility. signalsure 30 is aec-q101d qualifed. signalsure 30 is available in the following color wavelengths: C red orange (615nm) C super red (630nm) C super red (635nm) signalsure 30 low power solution features and benefits primary applications higher drive current capability for increased fux performance mirror/side repeater low thermal resistance for better hot lumen performance stop/tail economic package for high quantity tail lamp solutions C chmsl available in 615nm, 630nm and 635nm colors for increased design options aec-q101d qualifed automotive ds147 signalsure 30 product datasheet ?2016 lumileds holding b.v. all rights reserved. rohs compliant
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. i table of contents general product information 2 product test conditions .............................................................................. 2 part number nomenclature .......................................................................... 2 environmental compliance ........................................................................... 2 performance characteristics 3 product selection guide .............................................................................. 3 optical characteristics ............................................................................... 3 electrical and thermal characteristics .................................................................. 3 absolute ratings .................................................................................... 4 characteristic curves 4 spectral power distribution characteristics ............................................................. 4 light output characteristics .......................................................................... 5 forward current characteristics ....................................................................... 6 radiation pattern characteristics ...................................................................... 7 operating limits characteristics ....................................................................... 7 permissible pulse handling characteristics ............................................................. 8 product bin and labeling defnitions 9 designing with signalsure ............................................................................ 9 decoding product bin labeling ........................................................................ 9 luminous flux bins .................................................................................. 9 color codes ....................................................................................... 10 forward voltage bins ............................................................................... 10 mechanical dimensions 10 refow soldering guidelines 11 jedec moisture sensitivity ........................................................................... 11 solder pad design .................................................................................. 12 packaging information 13 pocket tape dimensions ............................................................................ 13 reel dimensions ................................................................................... 13 product labeling ................................................................................... 14
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 2 general product information product test conditions signalsure 30 leds are tested and binned using a 20ms monopulse (mp) at 30ma drive current, junction temperature, t j , of 25oc. part number nomenclature part numbers for signalsure 30 follow the convention below: a 1 d t C b c c c l 1 1 d e f g 0 0 where: b C designates color (o=red orange and s=super red) c c c C designates minimum dominant wavelength (612=612nm, 627=627nm and 632=632nm) d C designates minimum fux bin (see product bin and labeling section) e C designates the fux bin range (3=3 subsequent fux bins including the minimum bin) f g C designates forward voltage range in which f is the minimum v f bin and g is the maximum v f bin (see product bin and labeling defnitions section) therefore, the following part number is used for a signalsure 30 super red, 632nm minimum wavelength, luminous fux range of 1.5 lumens to 2.6 lumens and forward voltage range of 2.00 volts to 2.45 volts: a 1 d t C 6 l 1 1 1 3 a c 0 0 environmental compliance lumileds llc is committed to providing environmentally friendly products to the solid-state lighting market. signalsure 30 is compliant to the european union directives on the restriction of hazardous substances in electronic equipment, namely the rohs directive 2011/65/eu and reach regulation (ec) 1907/2006. lumileds llc will not intentionally add the following restricted materials to its products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (pbb) or polybrominated diphenyl ethers (pbde).
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 3 performance characteristics product selection guide table 1. product selection for signalsure 30 at 20ms mp, 30ma, t j =25c cl dmiat aelegt 12 nm pat mbe red orange 615 a1dt - o612l super red 630 a1dt - s627l super red 635 a1dt - s632l notes for table 1: 1. dominant wavelength is derived from the cie 1931 chromaticity diagram and represents perceived color. 2. lumileds maintains a tolerance of 1nm for dominant wavelength measurements. optical characteristics table 2. typical optical characteristics for signalsure 30 at 20ms mp, 30ma, t j =25c pat mbe tpical ttal iclded agle 1 2 a1dt - o612l 140 120 a1dt - s627l 140 120 a1dt - s632l 140 120 notes for table 2: 1. total angle at which 90% of total luminous fux is captured. 2. viewing angle is the of axis angle from lamp center line where the luminous intensity is ? of the peak value. electrical and thermal characteristics table 3. typical electrical and thermal characteristics for signalsure 30 at 20ms mp, 30ma, t j =25c paamete pefmace forward voltage, v f 2.1v electrical thermal resistance, r th j-c electr [1] (maximum) 100c/w real thermal resistance, r th j-c real [2] (maximum) 125c/w temperature coefcient of v f , i f = 30ma, 10c t j 110c -3.0mv/c 1rwhviru7deoh 1. r th j-c electr : electrical thermal resistance (junction to case). 2. r th j-c real : real thermal resistance (junction to case) with wall plug efciency included. reference je sd51-51, jesd51-14, 4.1.3.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 4 absolute ratings table 4. absolute ratings for signalsure 30. parameter performance minimum dc forward current 3ma maximum dc forward current 60ma maximum junction temperature [1] 125c operating case temperature at test current [1] -40c to 110c operating case temperature at maximum current [1] -40c to 110c led storage temperature -40c to 110c soldering temperature jedec 020c 260c allowable refow cycles 3 minimum esd performance [2] 2kv hbm (class 2), 1kv cdm (class iii) reverse voltage (v r ) -10v notes for 4: 1. proper current derating must be observed to maintain junction temperature below the maximum, so that the led is maintained below the maximum rated operating case temperature. signalsure leds driven at or above the maximum rated operating case temperature may have shorter lifetime. 2. measured using human body model (per ansi/esda/jedec js-001-2010) and charged device model (per jesd22-c101f). spectral power distribution characteristics figure 1. typical normalized power vs. wavelength for signalsure 30 at 20ms mp, 30ma, t
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 5 light output characteristics figure 2. typical normalized light output vs. junction temperature for signalsure 30 at 20ms mp, 30ma. figure 3. typical normalized light output vs. forward current for signalsure 30 at t j =25oc
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 6 forward current characteristics figure 4a. typical forward current vs. forward voltage for signalsure 30 at t j =25oc figure 4b. typical forward voltage shift vs. junction temperatu re for signalsure 30 at 20ms mp, specifed test current.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 7 radiation pattern characteristics operating limits characteristics figure 6. maximum forward current vs. case temperature for signalsure 30. figure 5. typical radiation pattern for signalsure 30 at 20ms mp, 30ma.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 8 permissible pulse handling characteristics figure 7. permissible pulse handling capability for signalsure 30.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 9 product bin and labeling defnitions designing with signalsure flux bins supportable for car programs depend on product color and program start- and end-of-production date. flux roadmaps by year and product color are maintained and available from the sales representative. please contact a local sales representative to request the fux bin range with best supportability for program timing. decoding product bin labeling in the manufacturing of semiconductor products, there are variations in performance around the average values given in the technical datasheets. for this reason, lumileds bins the led components for luminous fux or radiometric power, color point, peak or dominant wavelength and forward voltage. signalsure 30 leds are labeled using a 3-digit alphanumeric cat code following the format below: a b c where: a C designates luminous fux bin (example: 4=2.6 lumens to 3.0 lumens) b C designates color code (example: 3=612nm to 618nm) c C designates forward voltage bin (example: b=2.15v to 2.30v) therefore, a signalsure 30 with a lumen range of 2.6 to 3.0, color code of 3 and a forward voltage of 2.15v to 2.30v has the following cat code: 4 3 b luminous flux bins table 5 lists the standard luminous fux bins for signalsure 30 leds. product availability in a particular bin varies by color and platform start-of-production date. contact your local sales representative for best supportability of programs. table 5. luminous fux bin defnitions for signalsure 30 at 20ms mp, 30ma, t j =25c bin luminous flux (lm) minimum maximum 1 1.5 1.8 2 1.8 2.1 3 2.1 2.6 4 2.6 3.0 5 3.0 3.6 a 3.6 4.3 b 4.3 5.1 c 5.1 6.1 notes for tale 5 1. lumileds maintains a tolerance of 10% on luminous fux measurements.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 10 color codes table 6. color code defnitions for signalsure 30 at 20ms mp, 30ma, t j =25c cde dmiat aelegt nm miimm maimm 3 612 618 4 627 632 5 632 638 notes for table 6: 1. lumileds maintains a tolerance of 1nm on dominant wavelength measurements. forward voltage bins table 7. forward voltage bin defnitions for signalsure 30 at 20ms mp, 30ma, t j =25c bi fad ltage f miimm maimm a 2.00 2.15 b 2.15 2.30 c 2.30 2.45 notes for table 7: 1. lumileds maintains a tolerance of 0.06v on forward voltage measurements. mechanical dimensions notes for figure 8: 1. drawings are not to scale. 2. all dimensions are in millimeters. figure 8. mechanical dimensions for signalsure 30. ? cathode mark
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 11 refow soldering guidelines table 8. refow profle characteristics for signalsure 30. profile feature lead free assembly preheat minimum temperature (t smin ) 150c preheat maximum temperature (t smax ) 200c preheat time (t smin to t smax ) 60 to 120 seconds ramp-up rate (t l to t p ) 3c / second maximum liquidus temperature (t l ) 217c time maintained above temperature t l (t l ) 60 to 150 seconds peak / classifcation temperature (t p ) 260c time within 5c of actual temperature (t p ) 20 to 40 seconds ramp-down rate (t p to t l ) 6c / second maximum time 25c to peak temperature 8 minutes maximum notes for table 8: 1. all temperatures refer to the application printed circuit board (pcb), measured on the surface adjacent to the package body. jedec moisture sensitivity table 9. moisture sensitivity levels for signalsure 30. level floor life [1] soak requirements standard time conditions time conditions 2 1 year 30c / 60% rh 168 hours + 5 / - 0 85c / 60% rh notes for table 9: 1. shelf life 2 years figure 9. visualization of the acceptable refow temperature profle as specifed in table 8.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 12 solder pad design notes for figure 10: 1. the drawing shows the recommended signalsure 30 layout on printed circuit board (pcb). 2. all dimensions are in millimeters. figure 10. recommended pcb solder pad layout for signalsure 30.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 13 packaging information pocket tape dimensions reel dimensions notes for figures 11 and 12: 1. drawings are not to scale. 2. all dimensions are in millimeters. figure 12. reel dimensions for signalsure 30. figure 11. pocket tape dimensions for signalsure 30.
ds147 signalsure 30 product datasheet 20160508 ?2016 lumileds holding b.v. all rights reserved. 14 product labeling signalsure 30 leds are packaged in moisture barrier bags on reels. both moisture barrier bag and reels have printed information providing part numbers with cat codes that indicate luminous fux, color and forward voltage bins. figure 14. example of a product reel label. figure 13. example of a moisture barrier bag label.
?2016 lumileds holding b.v. all rights reserved. luxeon is a registered trademark of the lumileds holding b.v. in the united states and other countries. lumileds.com about lumileds lumileds is the global leader in light engine technology. the company develops, manufactures and distributes groundbreaking leds and automotive lighting products that shatter the status quo and help customers gain and maintain a competitive edge. with a rich history of industry frsts, lumileds is uniquely positioned to deliver lighting advancements well into the future by maintaining an unwavering focus on quality, innovation and reliability. to learn more about our portfolio of light engines, visit lumileds.com . ds147 signalsure 30 product datasheet 20160508 neither lumileds holding b.v. nor its afliates shall be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. although lumileds holding b.v. and/or its afliates have attempted to provide the most accurate information and data, the materials and services information and data are provided as is, and neither lumileds holding b.v. nor its afliates warrants or guarantees the contents and correctness of the provided information and data. lumileds holding b.v. and its afliates reserve the right to make changes without notice. you as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data.


▲Up To Search▲   

 